C
BULLETIN NUMBER: SWB-001
DATE ISSUED: July 19, 2001
DATE CLOSED: July 24, 2001 (Corrected in PowerMAX OS 4.3P8 & 5.1SR2)
AFFECTED SYSTEMS: Power Hawk Model 640, PowerStack II (MTX)
PROGRAM NAME: PowerMAX OS
RELEASE LEVEL: 4.3 & 5.1
EXPLANATION: A Power Hawk Model 640 or PowerStack II (MTX) system running the
PowerMAX OS 5.1 Operation System may panic shortly after an auto-reboot.
An auto-reboot can occur if a system administrator uses:
shutdown –g0 –y –i6 -or- init 6
to reboot the system. It may also occur if the system panics and the
system automatically reboots to take a system dump.
RESOLUTION: This problem is currently being addressed by Software Engineering. Until a fix
becomes available; however, the following procedure should be performed in reboots
to avoid the possibility of a subsequent system panic.
When rebooting the system do either: